CleanroomLink CleanroomLink
Menu
en
Englishen中文(繁体)zh-TWTiếng ViệtviBahasa MelayumsBahasa IndonesiaidTürkçetrDeutschdeEspañoles日本語jaFrançaisfr
Industrial cleanroom HVAC filtration

Industrial Pre-Filters for Cleanroom HVAC Systems

CleanroomLink supplies engineered pre-filtration solutions for overseas buyers, HVAC engineers, quality teams, and factory managers who need balanced particle capture, airflow, and operating cost.

Avoid energy waste

High initial resistance can force AHU fans to work harder and increase electricity costs.

Match the environment

Cardboard frames may be unsuitable for high-humidity food or pharmaceutical areas.

Size for airflow

Incorrect rated airflow can cause early clogging and production-disrupting maintenance.

Industrial pre-filters for cleanroom HVAC systems

Fast RFQ Guide

Have your dimensions and airflow data ready? Submit the application environment, target efficiency, frame material, quantity, and delivery requirement for a more accurate quotation.

Send requirements

Technical specifications

Parameter table for pre-filter selection

The values below describe the industrial pre-filter range. Final performance depends on the selected media, dimensions, airflow, sealing arrangement, and application. Items marked for confirmation should be finalized during the RFQ stage.

Parameter Specification / RFQ status
Filtration classG3–F9 under EN779 / MERV 5–16 under ASHRAE; exact class to be confirmed
Filtration efficiencyDepends on model, media, and test method; verify against application requirements
Rated airflowCustom in m³/h or CFM; confirm AHU design airflow and face velocity
Initial resistance30–150 Pa, model dependent
Recommended final resistance250–450 Pa; confirm with system operating limits
Filter mediaSynthetic, glass fiber, or cotton; select according to dust load and temperature
Frame materialGalvanized steel, aluminum, SS304, or cardboard; environment dependent
DimensionsCustom L × W × D in mm or inches
SealingPU, EVA, or EPDM gasket; confirm housing interface
Temperature / humidityUp to 80°C / 90% RH standard reference; confirm actual conditions
Dust holding capacityTo be confirmed by selected media and applicable ISO 16890 / ASHRAE 52.2 method
Leak testingAvailable on request; test scope and documentation to be confirmed
Applicable systemHVAC and AHU pre-filtration, including cleanroom multi-stage systems

Information we need

A useful RFQ starts with system data

A reliable pre-filters supplier or manufacturer needs more than a product name. These inputs allow the specification to be checked against the housing, fan duty, cleanliness target, and procurement volume.

Efficiency target

G4, M5, F7, MERV rating, or the required application and standard.

Physical fit

Length, width, depth, gasket position, access direction, and original part number if available.

Operating conditions

Airflow, temperature, humidity, dust type, cleanroom ISO class, and cleaning or replacement cycle.

Commercial scope

Expected quantity, wholesale schedule, destination, target delivery date, and documentation needs.

Selection logic

Typical configurations by filtration stage

Efficiency, resistance, and airflow must be evaluated together. A higher efficiency grade may improve particle capture but can also increase resistance. The correct configuration maintains the required airflow without overloading the AHU fan or shortening service life.

01 / Coarse stage

G3–G4

Captures larger dust particles and protects secondary filters in standard HVAC systems and outdoor-air intake applications.

02 / Medium stage

M5–M6

Used in multi-stage systems to protect finer filtration layers in general manufacturing and assembly environments.

03 / Fine pre-stage

F7–F9

Provides a final pre-filtration barrier before HEPA or ULPA stages where cleanroom air quality requires additional protection.

Lead-time drivers

Plan production around the details that change delivery

  • Standard or custom size: Standard dimensions typically ship within 5–7 business days; custom sizes require additional fabrication time.
  • Frame material: SS304 usually requires longer preparation than galvanized steel or aluminum.
  • Testing and reports: Third-party reports or on-site leak testing certifications add processing time and must be defined early.

Custom options

Configure the filter around the facility

Custom wholesale and OEM-style requirements can be reviewed during the technical quotation process.

Frame selection

Moisture-resistant frames for humid environments and SS304 for applications requiring corrosion resistance.

Media selection

Synthetic media for high dust loads or glass fiber media for higher-temperature applications.

Gasket configuration

PU, EVA, or EPDM options selected to support an airtight fit in the AHU housing.

Selection boundary

Pre-filters and HEPA filters serve different jobs

Pre-filters are selected for dust-holding capacity and lower resistance, helping protect downstream filtration. HEPA and ULPA filters target ultra-high efficiency and should not be exposed to heavy dust loads without suitable upstream protection.

Choose pre-filters for

  • • Bulk contaminant capture
  • • AHU and secondary-filter protection
  • • Higher dust-holding capacity

Use HEPA / ULPA downstream for

  • • Ultra-high efficiency filtration
  • • Controlled cleanroom air quality
  • • Final-stage particle control

FAQ

Questions procurement and engineering teams ask

How do I confirm the model if I do not have the original part number? +

Provide the frame dimensions, required efficiency class or application type, and AHU rated airflow. These details can be cross-referenced to suggest a compatible specification.

Which information has the greatest impact on price? +

The main cost factors are efficiency grade, frame material, dimensions, testing or documentation requirements, and order volume. SS304 is typically more expensive than galvanized steel.

Do you support custom sizes and configurations? +

Yes. Custom dimensions, frame materials, media, and gasket arrangements can be reviewed against the AHU housing and operating environment.

What if the required test data or standard is not yet confirmed? +

Submit the application, system data, and target market requirements. Efficiency, resistance, leak testing, and documentation can then be confirmed during the RFQ stage.

Send RFQ

Request a specification-matched pre-filter quote

For an accurate and cost-effective quotation, submit your application environment, target standard, filter specifications or AHU data, expected quantity, and required delivery schedule.

Email:

Office:

Information to include in your inquiry

  • Application environment and ISO class
  • Target standards: EN, ISO, or ASHRAE
  • Dimensions, airflow, and efficiency
  • Frame, media, and gasket requirements
  • Expected quantity and wholesale schedule
  • Required delivery date and documentation

Submit your complete requirements below to receive a pre-filter recommendation and quotation path from CleanroomLink.